Model NO.: YJV YJY YJV22 etc.
Wire Core Material: Copper/Aluminum Cable
Certification: ISO, CCC, CE
Model: Yjv Yjlv Yjy Yjly etc. Cable
Brand: Gdyg
Supply Record: America, Australia, African Countries, Arabian Co
Sepcial Applicaton: Low Smoke Power Cable
Key Word 1: PVC Power Cable
Fire Resistant: Yes
Aroumoured Type: Steel Wire, Aluminum Wire
Business Type: Manufacturer
Key Words: Armoured Cable
Key Word: Copper/Aluminum Cable
Standard: ISO, 3c, IEC,60502, IEC60227, an/Nz etc
Characters: Swa, Sta, Insulated Cable
Trademark: GDYG
Transport Package: Wooden Reel, Steel Reel etc.
Specification: 0.5-630 mm2
Origin: Guangdong, China
HS Code: 8544492100
Model NO.: YJV YJY YJV22 etc.
Wire Core Material: Copper/Aluminum Cable
Certification: ISO, CCC, CE
Model: Yjv Yjlv Yjy Yjly etc. Cable
Brand: Gdyg
Supply Record: America, Australia, African Countries, Arabian Co
Sepcial Applicaton: Low Smoke Power Cable
Key Word 1: PVC Power Cable
Fire Resistant: Yes
Aroumoured Type: Steel Wire, Aluminum Wire
Business Type: Manufacturer
Key Words: Armoured Cable
Key Word: Copper/Aluminum Cable
Standard: ISO, 3c, IEC,60502, IEC60227, an/Nz etc
Characters: Swa, Sta, Insulated Cable
Trademark: GDYG
Transport Package: Wooden Reel, Steel Reel etc.
Specification: 0.5-630 mm2
Origin: Guangdong, China
HS Code: 8544492100
Steel Wire Armoured Power Cable for Underground
Constrution Sketch
Constrution Sketch

Characteristics & Applications
Â
The main feature of the flame retardant XLPE power cable is hard to get fire or that the continous burning of cables is vert limited when it is on fire. It applies to the places with many cable is laid tightly together such as power-generated station, subway, tunnel, hight-storey building, large-sized factory and mines, oil field and coal mine.
Â
Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.Â
Basic Information
Model No: YJV YJLV VV VLV VY VLY VV22 VV23 VV33 etc.       Material Shape: Round Wire
Range of Application: Power Grid and All Industry Â
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYGÂ
Specification: 0.5mm2 - 630mm2 Â Â Â Â Â
Supply Record: America, Australia, African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
Application: Power Grid, Transmission Line, Construction, Railway Transportation, Chemical Plant, Telecom , Oil Industry, Equipment Manufacture, Instrument Industry etc..
Voltage: 35KV, 10KV, 0.6/1KV, 450/750V, 300/500V
Current: AC & DC
Insulation Material: XLPE, PVC etc.
Sheath Material: XLPE, PVC etc.
Material Shape: Round wire
Application
2. Maximum conductor temperature under normal operation is 90ºC.
3. Maximum conductor temperature under short circuit (Max duration is not more than 5s) is not more than 250ºC.
4. Minimum installation ambient temperature is not less than 0ºC.
  Installation bending radius are not less than the following specified values:
  Single core non-armored cable: 20D
  Single core armored cable: 15D
  3 cores non-armored cable: 15D
  3 cores armored cable: 12D
  (Note: D-outer diameter of cable)
Technical Parameters
Voltagela class   26/35kV
Type: YJV YJLV ZC-YJV ZC-YJLV
nominal cross-section mm |
insulation thickness mm |
O.D. mm |
capacitance μF/km |
approx. ampacity (air)  A |
approx. ampacity buried A |
reference weight of finished cable kg/km |
|||
Cu | Al | Cu | Al | Cu | Al | ||||
50 | 10.5 | 38.8 | 0.12 | 245 | 190 | 225 | 175 | 1745 | 1435 |
70 | 10.5 | 40.7 | 0.13 | 305 | 235 | 275 | 215 | 2025 | 1591 |
95 | 10.5 | 42.3 | 0.15 | 370 | 285 | 330 | 255 | 2330 | 1742 |
120 | 10.5 | 43.9 | 0.16 | 425 | 330 | 375 | 290 | 2647 | 1903 |
150 | 10.5 | 45.5 | 0.17 | 485 | 375 | 420 | 325 | 2998 | 2068 |
185 | 10.5 | 47.3 | 0.18 | 555 | 430 | 475 | 370 | 3414 | 2218 |
240 | 10.5 | 49.7 | 0.19 | 650 | 505 | 555 | 430 | 4044 | 2556 |
300 | 10.5 | 51.9 | 0.21 | 745 | 580 | 630 | 490 | 4696 | 2836 |
400 | 10.5 | 55.3 | 0.23 | 870 | 680 | 720 | 565 | 5801 | 3320 |
500 | 10.5 | 60.3 | 0.25 | 1000 | 790 | 825 | 645 | 7132 | 4032 |
630 | 10.5 | 64.5 | 0.28 | 1160 | 920 | 940 | 740 | 8515 | 4609 |
Voltagela class   12/20kV
Type: YJV22 YJLV22 ZC-YJV22 ZC-YJLV22
nominal cross-section mm |
insulation thickness mm |
O.D. mm |
capacitance μF/km |
approx. ampacity (air)  A |
approx. ampacity buried A |
reference weight of finished cable kg/km |
|||
Cu | Al | Cu | Al | Cu | Al | ||||
3X25 | 5.5 | 55.5 | 0.22Â | 129 | 100 | 155 | 120 | 3833 | 3476 |
3X25 | 5.5 | 57.9 | 0.25Â | 156 | 120 | 185 | 144 | 4313 | 3702 |
3X50 | 5.5 | 61.1 | 0.26Â | 184 | 143 | 218 | 169 | 5281 | 4311 |
3X70 | 5.5 | 64.9 | 0.28Â | 229 | 177 | 267 | 207 | 5878 | 4399 |
3X95 | 5.5 | 68.8 | 0.30Â | 275 | 213 | 319 | 247 | 6867 | 4770 |
3X120 | 5.5 | 72.2 | 0.32Â | 316 | 246 | 363 | 282 | 7906 | 5192 |
3X150 | 5.5 | 75.8 | 0.33Â | 363 | 281 | 412 | 319 | 9045 | 5554 |
3X185 | 5.5 | 79.9 | 0.35Â | 408 | 317 | 460 | 357 | 10435 | 6070 |
3X240 | 5.5 | 86.4 | 0.38 | 178 | 372 | PS Frame,Mirror Frame,Picture Frame Household Items,Primed Moulding,Ps Cornice Co., Ltd. , http://www.nshouseholditems.com |