SSTP Cat7 Network Patch Cable/Patch Cord
Â
 Product Name |  High Speed Cat7 SSTP Cable | |
 Coductor |  Copper / Aluminum, based on client's requirements | |
Construction | Â Bare copper wire | |
 Insulation jacket | ||
 SSTP sheath/ Braid | ||
Colors |  Assorted upon request |
|
Voltage | Â low voltage |
|
Application | Â Ethernet 10-100 Base-TX ATM Trunk wiring 100VG-Anylan 1000 Base-T Multi-media. |
|
Specifications | Â CCC ISO certificated |
|
 Strict QC | ||
 Prompt delivery | ||
OEM/ODM | Â Available | |
Sample |
 Free, freight charge prepaid or negotiation |
Physical Specifications:
CONDUCTOR
- Â Â Â Â Raw material of the conductor: CU
-     Conductor Dia.: 0.585±0.003mm (23AWG)
INSULATION
- Â Â Â Â Raw material of the conductor: F-PE
- Â Â Â Â Quantity:4 twisted pairs
-     Insulation Dia. : 1.5±0.005mm
- Â Â Â Â Average thickness: 0.4625mm
- Â Â Â Â Minimum point thickness: 0.46mm
TWISTED PAIRS SCREEN
- Â Â Raw material of the screen: Aluminum Mylar shield
-   Overlap rate:≥25%
JACKET RIP CORD: Nylon thread
Â
SHEATH
- Â Â Â Â Sheath material:Â PVC (Availabled in PE or LSZH)
-     Nominal Dia.: 7.5±0.2mm
- Â Â Â Â Average thickness: 0.6mm
- Â Â Â Â Minimum point thickness: 0.5mm
Â
Â
Â
Â
Specification Details                             Â
1. Conductor:26/28 AWG Solid/Stranded BC
2. Insulation:Solid polyolefin.
3. Cabling:4 twisted pairs cabled around a cross shaped central filler into the cable core.
4. Shielding:Aluminum Mylar Spirally Wrapped(FTP)
5. Braiding:TC/Aluminum Magnesium alloy Solid(SFTP)
6. Jacket:PVC/FR-PVC/LSOH
Â
COMPLIANCE WITH
1. ISO/IECÂ 11801
2. TIA/EIA-568-B.2
3. IEC-60332-1
4. ULÂ 444Â (CM/CMR/CMPÂ grade)
5. RoHS
Â
Â
ELECTRICALÂ Â PROPERTIES | ||||||||
Conductor Resistance |
Max. 138  ohms/km at 20ºC |
|||||||
Insulation Resistance |
Min.  5000  mega  ohms-km at 20ºC |
|||||||
Dielectric Test  |
1000V DC /1 min  ; No Breakdown |
|||||||
Temperature Rating |
75ºC |
|||||||
Voltage Rating |
30V |
|||||||
f(MHZ) |
Zin-OS |
Fitted Z |
SRL |
ATT(PATCH) |
DELAY |
MAX. DELAY SKEW(ns/100M) |
NEXT |
PSNEXT |
0.772 |
100±15 |
100±15 |
19.40Â |
1.8 |
574.97 |
45.0 |
67 |
64 |
1 |
20.00Â |
2 |
570 |
45.0 |
65.3 |
62.31 |
||
4 |
23.00Â |
4.1 |
552.00 |
45.0 |
56.3 |
53.28 |
||
8 |
24.50Â |
5.8 |
546.73 |
45.0 |
51.8 |
48.77 |
||
10 |
25.00Â |
6.5 |
545.38 |
45.0 |
50.3 |
47.31 |
||
16 |
25.00Â |
8.2 |
543.00 |
45.0 |
47.3 |
44.25 |
||
20 |
25.00Â |
9.3 |
542.05 |
45.0 |
45.8 |
42.8 |
||
25 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
31.25 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
62.5 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
100 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
250 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
350 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
500 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
550 |
21.50Â |
17 |
538.55 |
45.0 |
38.4 |
35.38 |
||
600 |
20.10Â |
22 |
537.60 |
45.0 |
35.3 |
32.31 |
Â
Company information
Shenzhen Light Blue Electronics Co., Ltd. is a leading professional manufacturer of cable assembly. Our products include HDMI cable, USB3.0/2.0 cable, VGA CABLE,MHL Cable, (DP)Displayport Cable, SATA cable, Network Lan Cat cable, AV cable, Coaxial cable,DVI cable, HDMI adapter, HDMI splitter, HDMI switch, HDMI extender, HDMI repeater, Chargers, Earphone cable, which all attained "CE", "UL", "FCC" and "RoHS", "ATC", ISO9001:2008, ISO14001:2004 certificates, and they have been sold to America, England, Mexico, Germany, Chile, Greece, Australia and European countries. We guarantee each product will be Full-checked 100%. If there are bad products, we will promptly pay compensation to customers without any charge.
Package informationÂ
1pcs/poly bag
250pcs/carton
carton size:46*30*25cm
FAQ
With years of export experience along with excellent quality, advanced services and competitive prices, YITAILI has won numerous customers' trust and support.More detail please contact us.
Payment term?
(1)Payment:T/T only,30%deposit,the balance before delivery.
(2)Production leading time:10-15days,see qty to confirm.
(3)Shipping out:Guangzhou or Shenzhen
Certification
CE,ROHS
Â
SSTP Cat7 Network Patch Cable/Patch Cord
Â
 Product Name |  High Speed Cat7 SSTP Cable | |
 Coductor |  Copper / Aluminum, based on client's requirements | |
Construction | Â Bare copper wire | |
 Insulation jacket | ||
 SSTP sheath/ Braid | ||
Colors |  Assorted upon request |
|
Voltage | Â low voltage |
|
Application | Â Ethernet 10-100 Base-TX ATM Trunk wiring 100VG-Anylan 1000 Base-T Multi-media. |
|
Specifications | Â CCC ISO certificated |
|
 Strict QC | ||
 Prompt delivery | ||
OEM/ODM | Â Available | |
Sample |
 Free, freight charge prepaid or negotiation |
Physical Specifications:
CONDUCTOR
- Â Â Â Â Raw material of the conductor: CU
-     Conductor Dia.: 0.585±0.003mm (23AWG)
INSULATION
- Â Â Â Â Raw material of the conductor: F-PE
- Â Â Â Â Quantity:4 twisted pairs
-     Insulation Dia. : 1.5±0.005mm
- Â Â Â Â Average thickness: 0.4625mm
- Â Â Â Â Minimum point thickness: 0.46mm
TWISTED PAIRS SCREEN
- Â Â Raw material of the screen: Aluminum Mylar shield
-   Overlap rate:≥25%
JACKET RIP CORD: Nylon thread
Â
SHEATH
- Â Â Â Â Sheath material:Â PVC (Availabled in PE or LSZH)
-     Nominal Dia.: 7.5±0.2mm
- Â Â Â Â Average thickness: 0.6mm
- Â Â Â Â Minimum point thickness: 0.5mm
Â
Â
Â
Â
Specification Details                             Â
1. Conductor:26/28 AWG Solid/Stranded BC
2. Insulation:Solid polyolefin.
3. Cabling:4 twisted pairs cabled around a cross shaped central filler into the cable core.
4. Shielding:Aluminum Mylar Spirally Wrapped(FTP)
5. Braiding:TC/Aluminum Magnesium alloy Solid(SFTP)
6. Jacket:PVC/FR-PVC/LSOH
Â
COMPLIANCE WITH
1. ISO/IECÂ 11801
2. TIA/EIA-568-B.2
3. IEC-60332-1
4. ULÂ 444Â (CM/CMR/CMPÂ grade)
5. RoHS
Â
Â
ELECTRICALÂ Â PROPERTIES | ||||||||
Conductor Resistance |
Max. 138  ohms/km at 20ºC |
|||||||
Insulation Resistance |
Min.  5000  mega  ohms-km at 20ºC |
|||||||
Dielectric Test  |
1000V DC /1 min  ; No Breakdown |
|||||||
Temperature Rating |
75ºC |
|||||||
Voltage Rating |
30V |
|||||||
f(MHZ) |
Zin-OS |
Fitted Z |
SRL |
ATT(PATCH) |
DELAY |
MAX. DELAY SKEW(ns/100M) |
NEXT |
PSNEXT |
0.772 |
100±15 |
100±15 |
19.40Â |
1.8 |
574.97 |
45.0 |
67 |
64 |
1 |
20.00Â |
2 |
570 |
45.0 |
65.3 |
62.31 |
||
4 |
23.00Â |
4.1 |
552.00 |
45.0 |
56.3 |
53.28 |
||
8 |
24.50Â |
5.8 |
546.73 |
45.0 |
51.8 |
48.77 |
||
10 |
25.00Â |
6.5 |
545.38 |
45.0 |
50.3 |
47.31 |
||
16 |
25.00Â |
8.2 |
543.00 |
45.0 |
47.3 |
44.25 |
||
20 |
25.00Â |
9.3 |
542.05 |
45.0 |
45.8 |
42.8 |
||
25 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
31.25 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
62.5 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
100 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
250 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
350 |
24.30Â |
10.4 |
541.20 |
45.0 |
44.3 |
41.35 |
||
500 |
23.60Â |
11.7 |
540.44 |
45.0 |
42.9 |
39.89 |
||
550 |
21.50Â |
17 |
538.55 |
45.0 |
38.4 |
35.38 |
||
600 |
20.10Â |
22 |
537.60 |
45.0 |
35.3 |
32.31 |
Â
Company information
Shenzhen Light Blue Electronics Co., Ltd. is a leading professional manufacturer of cable assembly. Our products include HDMI cable, USB3.0/2.0 cable, VGA CABLE,MHL Cable, (DP)Displayport Cable, SATA cable, Network Lan Cat cable, AV cable, Coaxial cable,DVI cable, HDMI adapter, HDMI splitter, HDMI switch, HDMI extender, HDMI repeater, Chargers, Earphone cable, which all attained "CE", "UL", "FCC" and "RoHS", "ATC", ISO9001:2008, ISO14001:2004 certificates, and they have been sold to America, England, Mexico, Germany, Chile, Greece, Australia and European countries. We guarantee each product will be Full-checked 100%. If there are bad products, we will promptly pay compensation to customers without any charge.
Package informationÂ
1pcs/poly bag
250pcs/carton
carton size:46*30*25cm
FAQ
With years of export experience along with excellent quality, advanced services and competitive prices, YITAILI has won numerous customers' trust and support.More detail please contact us.
Payment term?
(1)Payment:T/T only,30%deposit,the balance before delivery.
(2)Production leading time:10-15days,see qty to confirm.
(3)Shipping out:Guangzhou or Shenzhen
Certification
CE,ROHS
Â
1.50mm Wire To Board Connectors
1.50mm Wire To Board Connectors:Line to board has rubber shell, terminal and needle holder.
The wire to board connector connects the wires to the printed circuit board (PCB) to realize the connection between circuits. Our line to board connectors focus on flexibility and reliability, suitable for small size plug-in and safe termination, and are equipped with friction locking mechanism or full locking mechanism. Our lcedi connectors provide excellent performance in both low voltage differential signaling (LVDS) and embedded DisplayPort (EDP) applications. Our economical power supply (EP) connectors have up to 12 locations, so your product can reliably deliver power to circuit boards when space is limited. We offer PCB male terminals with multiple or single connection types, including bolt mounting, printed circuit mounting, wire crimping, testing, soldering, and mounting frames for quick disconnect applications.
1.50mm Wire To Board Connectors
ShenZhen Antenk Electronics Co,Ltd , https://www.atkconnectors.com